Careers

Retaining Concrete Wall

Retaining Concrete Wall

Moore Concrete design and manufacture bespoke Precast Retaining Concrete Walls  that are L Shaped to suit most site conditions.

We cover all market sectors, from back gardens to major civil engineering infrastructure projects and continuously strive to deliver a first class service based on value engineered solutions to suit individual project requirements.

We are delighted to be able to use our expertise to guide to the best solution for your particular project, from design and tender stage through to a detailed quotation specific to your requirements.

Road Retaining Wall

Our Precast Retaining wall design is manufactured as an L-shaped panel and they are a versatile and sustainable solution. These are applicable to the public, residential and commercial sectors. Installation is seamless and can be easily relocated.

For further information regarding Retaining Concrete Wall Please contact a member of our civil Sales Team on 028 2565 2566, Ext 3
Download Brochure
Please fill in your details to download brochure

I have read the Privacy Policy and agree to the terms and conditions.

  • Features & Specifications
  • Product Dimensions

    Precast Retaining Wall Dimensions

    Moore Concrete are proud to be one of the UK’s leading manufacturers of high quality precast building products. We have a wide range of L-shaped Walls available in heights of 2.425m (8’), 3.0m (10’) 4.0m (13’), 5.0m (16’5”) and 6.0m (20’). These can be manufactured to bespoke sizes and customer specifications.

  • Delivery
    Delivery & Install Options

    Free Standing Retaining L Walls are CE Marked – Manufactured to EN 15258.

    Moore Concrete free standing retaining walls are designed by Chartered Structural Engineers in accordance with EN1992:1-1 and BS5502 Part 22 2003. Please see Declaration of Performance for further information.

    • Free standing retaining walls are shipped on their sides due to height restrictions and for stability.

    • Provision for lifting is made with 2Nr 16mm sockets which are cast into the unit. Lifting loops can be supplied by Moore Concrete.

    • If using a fork truck an approved fork mounted hook attachment should be used. This mounted hook should be secured to the forks to prevent movement. If fork toes are not available an approved spreader beam should be used for use with a hiab, crane or digger.

    • The units should be laid safely on the ground on timber skids/lathes to prevent damage to the unit.

    • Lifting Loops will correspond to the load being lifted. Loops can be subjected to a diagonal lift up to 45°.

    Moore Concrete will deliver your products to site. For full installation and handing guidance please refer to Storage and Handling Instructions for Free Standing Retaining Walls.

    For further information regarding L Shaped Retaining Walls please contact a member of our Civils sales team on 028 2565 2566, Ext 3.
    Our precast retaining wall units can be delivered to any part of the UK and Ireland.

Precast Retaining Wall Dimensions

Moore Concrete are proud to be one of the UK’s leading manufacturers of high quality precast building products. We have a wide range of L-shaped Walls available in heights of 2.425m (8’), 3.0m (10’) 4.0m (13’), 5.0m (16’5”) and 6.0m (20’). These can be manufactured to bespoke sizes and customer specifications.

Delivery & Install Options

Free Standing Retaining L Walls are CE Marked – Manufactured to EN 15258.

Moore Concrete free standing retaining walls are designed by Chartered Structural Engineers in accordance with EN1992:1-1 and BS5502 Part 22 2003. Please see Declaration of Performance for further information.

• Free standing retaining walls are shipped on their sides due to height restrictions and for stability.

• Provision for lifting is made with 2Nr 16mm sockets which are cast into the unit. Lifting loops can be supplied by Moore Concrete.

• If using a fork truck an approved fork mounted hook attachment should be used. This mounted hook should be secured to the forks to prevent movement. If fork toes are not available an approved spreader beam should be used for use with a hiab, crane or digger.

• The units should be laid safely on the ground on timber skids/lathes to prevent damage to the unit.

• Lifting Loops will correspond to the load being lifted. Loops can be subjected to a diagonal lift up to 45°.

Moore Concrete will deliver your products to site. For full installation and handing guidance please refer to Storage and Handling Instructions for Free Standing Retaining Walls.

For further information regarding L Shaped Retaining Walls please contact a member of our Civils sales team on 028 2565 2566, Ext 3.
Our precast retaining wall units can be delivered to any part of the UK and Ireland.

Get In Touch

Complete The Form For A Free Quotation Or Advice

I have read the Privacy Policy and agree to the terms and conditions.

Contact Us

Enquiries

I have read the Privacy Policy and agree to the terms and conditions.